IBM SPSS Statistics - Participant-Level Re-runs

Version used: Version 31.0.1.0 (49)

PROCESS Version used: v4.2_beta


  • Question 1 - Are the confidence intervals in Table 2 and the error bars in Figure 5 too narrow? Recalculate them across participants within each condition. This addresses Assessment 2 supervisor comments 3, 5 and 11 about treating 2,688 ratings as independent observations.

  • Question 2 - Does the mediation result hold when the unit of analysis changes? Optionally repeat PROCESS Model 4 on participant-by-condition means and compare it with the pooled-rating model in recreate3.md.


1 - Participant-level confidence intervals (Question 1)

Why run this?

Aggregate the ratings

Calculate the intervals

Results and use in Table 2 and Figure 5

Measure Quadrant Participant means (n) M SD of participant means SE 95% CI
Unexpectedness 1 84 1.5179 0.4906 0.0535 [1.4114, 1.6243]
Unexpectedness 2 84 1.4077 0.5550 0.0606 [1.2873, 1.5282]
Unexpectedness 3 84 4.2217 0.5098 0.0556 [4.1111, 4.3324]
Unexpectedness 4 84 4.3452 0.4799 0.0524 [4.2411, 4.4494]
Discomfort 1 84 1.4747 0.4041 0.0441 [1.3870, 1.5624]
Discomfort 2 84 1.6622 0.5256 0.0574 [1.5481, 1.7763]
Discomfort 3 84 2.1652 0.6756 0.0737 [2.0186, 2.3118]
Discomfort 4 84 2.5149 0.6541 0.0714 [2.3729, 2.6568]

2 - Mediation sensitivity to the unit of analysis (Question 2; optional)

Why run this?

Prepare the aggregated dataset

Run the same PROCESS model

Results and comparison

Path Effect SE (HC4 or BootSE) 95% CI p
a (oddity → unexpectedness) 2.8207 0.0559 [2.7107, 2.9306] < .001
b (unexpectedness → discomfort, controlling oddity) 0.3772 0.0564 [0.2663, 0.4881] < .001
c (total) 0.7716 0.0628 [0.6480, 0.8952] < .001
c′ (direct) −0.2924 0.1652 [−0.6173, 0.0325] .078
a×b (indirect) 1.0640 0.1575 (BootSE) [0.7533, 1.3734] —